Menu
A+ A A-

Please scroll down for menus

Tim Taylor

Tim Taylor

Tim joined The Cyprus Institute in October 2015. He has an MSc in Information Systems and an honours Bachelor degree in Marketing. Tim has 23 years experience in IT. Prior to joining The Cyprus Institute he has held positions as web developer, database admin and project manager for private sector and governmental employers in Cyprus and UK.

Πώς θα Διευκολύνουμε την Πράσινη Μετάβαση για τα Ευάλωτα Νοικοκυριά; Προτάσεις με Βάση τα Πορίσματα της Συμπεριφορικής Επιστήμης

Green Transition For Vulnerable Households? Insights From Behavioral Science On What Works (And What Doesn’t)

CaSToRC Seminar: Dendritic Contributions to Learning in Biological and Artificial Networks

Seminar: How the ChEESE CoE is Developing HPC-based Software and Services to Address Natural Hazards

CY-MATHS-IN Seminar: For What the Bell Tolls

CyI and Cyprus Police Expand Their Collaboration

Regional Cooperation Through Electricity Trade Improves Both Environmental Sustainability and Energy Security in the Eastern Mediterranean and Middle East

Seminar: Towards Exascale Physically-based Computational Hydrology

“Unseen Gaze: The Hidden Portrait Under Titian's Ecce Homo": Exhibition Presenting CyI Research a Great Success, Receives Worldwide Media Attention

HIPERDISCO - High-Performance, Data-Intensive, and Scientific Computing Joint Master Design

  1. August 2016
  2. September 2016
For the initial monitoring of the building the SUI CyI research team installed a weather station on the roof, placed sensors inside the building and performed a thermal comfort assessment survey.

1. Climate data monitoring

Exterior
A Vantage Pro2 weather station was placed on the building roof to collect data from the SUI area. Regularly updated information about the climatic conditions could be found on the station webpage: http://www.weatherlink.com/user/suitepakcy/. The weather station base was designed and installed by the CyI technical equipment development team.

Interior
Twelve (12) HOBO data-loggers were placed in the building, for collecting temperature, humidity and light data. The data are collected every 30 minutes and will be elaborated with the HOBOware software.

2. Thermal comfort assessment questionnaire

A survey on occupant comfort satisfaction with the indoor environment in summer was conducted. The questionnaire was based on templates proposed by the HSE (http://www.hse.gov.uk/temperature/index.htm). A third of the total employees were asked and complementary measurements were made using a Heat Stress WBGT (Wet Bulb Globe Temperature) Meter, both for the indoor and the outdoor climatic conditions at the time of the survey.

Images below, from left to right:
Left: The Vantage Pro2 weather station
Middle: HOBO data logger placed in the working place – 1st floor
Right: Completed questionnaire (first page) – Ground floor.

1. Thermal imaging

Thermal images were taken using a T440 Flir thermal camera in order to find missing, damaged, or inadequate insulation, building envelope air leaks, moisture intrusion and other problems. Also, the main sources of radiant temperature were determined.

2. HOBO sensors data collection and analysis

The temperature, humidity, air movement and dew point data from the HOBO sensors were collected and analysed. The mean predicted vote (PMV) was calculated using the CBE Thermal Comfort Tool (http://comfort.cbe.berkeley.edu/EN). In all the spaces under monitoring the people are expected to be in thermal comfort, since all values are within the thermal comfort range of -0.7

Images below, from left to right:
Left: A thermal image from the mezzanine
Right: Graph. Thermal Comfort PMV

Publications & Media